- Input & output fully isolated with USB output port
- High Surge: High surge current capability starts difficult loads such as TVS; camps; motors and other inductive loads.
- Soft start: Smooth start-up of the appliances.
- Pure Sine Wave Output Waveform: Clean power for sensitive loads.
- AC output identical to and in some cases better than the power supplied by your utility.
- Cooling Fan: Control by load or temperature (optional)
- Low Total Harmonic Distortion: below 3%
MODEL
|
TS150-122
|
TS150-242
|
TS200-122
|
TS200-242
|
TS300-122
|
TS300-242
|
OUTPUT
|
AC Voltage
|
220/230/240 VAC
|
Rated Power
|
150W
|
200W
|
300W
|
Surge Power
|
300W (for few seconds)
|
400W (for few seconds)
|
600W (for few seconds)
|
USB
|
5V, 500mA or 2.1A (optional)
|
Waveform
|
Pure Sine Wave (THD < 3%)
|
Frequency
|
50/60Hz ± 3Hz
|
AC Regulation
|
± 5%
|
Standard Receptacles
|
A, B, C, D, E, F, G, H, I, GFCI (optional above)
|
LED Indicator
|
Green for power on, Red for failure / Protection Status Indication
|
INPUT
|
No Load Current Draw
|
≤ 0.5A
|
DC Voltage
|
12V
|
24V
|
12V
|
24V
|
12V
|
24V
|
Voltage Range
|
9.5 ~ 16.0 VDC
|
19.0 - 32.0 VDC
|
9.5 ~ 16.0 VDC
|
19.0 - 32.0 VDC
|
9.5 ~ 16.0 VDC
|
19.0 - 32.0 VDC
|
Efficiency (Typ.)
|
> 90%
|
> 90%
|
> 90%
|
> 90%
|
> 90%
|
> 93%
|
Fuse
|
20A*1
|
10A*1
|
30A*1
|
15A*1
|
40A*1
|
20A*1
|
DC Cable
|
BVR2.5m2*2
|
BVR1.5m2*2
|
BVR2.5m2*2
|
BVR1.5m2*2
|
BVR4m2*2
|
BVR2.5m2*2
|
PROTECTION
|
Battery Low Alarm
|
11 ± 0.5V DC
|
22 ± 1V DC
|
11 ± 0.5V DC
|
22 ± 1V DC
|
11 ± 0.5V DC
|
22 ± 1V DC
|
Battery Low Shutdown
|
10 ± 0.5V DC
|
20 ± 1V DC
|
10 ± 0.5V DC
|
21 ± 1V DC
|
10 ± 0.5V DC
|
21 ± 1V DC
|
Overload
|
Shutdown
|
Over Voltage
|
15.5 ± 0.5V DC
|
29.6 ± 1V DC
|
14.8 ± 0.5V DC
|
29.6 ± 1V DC
|
14.8 ± 0.5V DC
|
29.6 ± 1V DC
|
Over Temperature
|
Shut-off output voltage, recover automatically after temperature goes down
|
Short Circuit
|
Shut-off output voltage, repower onto recover
|
Battery Reverse Polarity
|
By fuse open
|
Soft Start
|
Yes, 5 ~ 10s
|
Earth Leakage
|
Yes
|
ENVIRONMENT
|
Reset Voltage After LVS
|
11.8 ~ 12.8V DC
|
23.6 ~ 25.6V DC
|
11.8 ~ 12.8V DC
|
23.6 ~ 25.6V DC
|
11.8 ~ 12.8V DC
|
23.6 ~ 25.6V DC
|
Working Temperature
|
0 - 40°C
|
Working Humidity
|
20% - 90% RH non-condensing
|
SAFETY & EMC
|
Storage Temperature & Humidity
|
-30°C - 70°C 22° F-185°F, 10-95%
|
Safety Standards
|
UL458 (only for GFCI receptacle)
|
Isolation Resistance
|
I/P-O/P: 1000Ohms / 500V DC
|
EMI Conduction & Radiation
|
Compliance to EN55022 Class A
|
EMS Immunity
|
Compliance to EN61000-3-2, 3
|
LVD
|
Compliance to EN60950-1: 2006 + A11: 2009
|
E-Mark
|
Compliance to E8*72/245/EEC, 95/54/EC
|
OTHERS
|
Dimensions
|
226*108*62 mm
|
Packing
|
1.27 Kg, 16pcs/20.8 Kg/Ctn (53.5*34*30.5 cm)
|
Cooling Fan
|
Control by load / temperature (optional)
|
Application
|
Home and office appliance, Power tools and portable equipments, Vehicle and solar power systems...etc.
|
|
Weight |
630Gr |
Имя файла |
Расширение файла |
операция |